Home > Buy Now > Monitoring & Diagnostic Equipment > X-Ray Equipment > X-Ray
 

Trade Ok
Member since 2008

Sehwa Medical Systems Co., Ltd.
 
icon New Product
icon X-Ray

line

icon Company Profile
icon Selling Leads
icon Bulletin Board
icon Guest Book
icon Index
icon e-Book

line


icon To Korean Page
icon To Chinese Page




visitors: 13568
 
Contact us
Sehwa Medical Systems Co., Ltd.
[Korea]
Address:
621-14 Docheon-dong, Gwangsan-gu, Gwangju 506-301 Korea
Phone:
82-62-9523251
Contact name:
Young-pyo, Kim , President
Inquire now









Sehwa Medical Systems Co., Ltd.
 
X-Ray

X-Ray

Inquire now

X-Ray

Click to enlarge image

 Model Number SMS-525-MF, 550-MF, 650-MF

Diagnostic X-ray Generators

500mA/125kVp, 500mA/150kVp,
600 mA/150kVp R/F X-ray Generator

  • Microprocessor control system!!
  • Digital display & membrane switch!!
  • 72 preset anatomical programs!!
  • Self-diagnosing function!!
  • Good design & easy handling!!

SMS-525-MF

Generator

  1. Micom control & digital display
  2. Power supply : 220V, 50/60Hz, single phase
  3. Pwer consumption : 35KVA
  4. Maximum output ratings
    - 100mA at 100 KVP
    - 80mA at 125 KVP
  5. Indication meter :
    - KVP, Time, mA, mAs
    - LED Lamp full indication
  6. Radiographic mode
    - mA setting : 50mA to 500mA
    - KVP setting : 45KVP to 125KVP
    - Time setting : 1/120 to 5sec. (50 steps)
  7. Spot radiographic mode
    - mA setting : 150mA to 300mA
    - KV setting : 45KVP to 125 KVP
    - Time setting : 1/120 ~ 5sec (50steps)
  8. Fluoroscopic mode
    - mA setting : 0.5mA to 3.0mA (5steps)
    - KV setting : 50KVP to 120 KVP
    - Maximum radiation time : 5min.
  9. Anatomical mode
    - 72 preset anatomical programs.
  10. Self-diagonosing function
    - Over load. Back up, Error code
  11. Dimension (W x D x H)
    - 630 x 400 x 820mm

H/V Transformer

  1. Insulating oil-filled unit
  2. maximum output ratings
    - 500mA at 100KVP
    - 300mA at 125KVP
  3. Fluoroscopy output ratings
    - 0.5mA at 120KVP
    - 3mA at 125 KVP
  4. Filament transformer
    - small output : 100V : 16V
    - large output : 100V : 24V
  5. High tension silicon rectification
  6. Maximum output capacity : 35KVA

SMS-550-MF

Generator

  1. Micom control & digital display
  2. Power supply : 220V, 50/60Hz, single phase
  3. Pwer consumption : 45KVA
  4. Maximum output ratings
    - 500mA at 100 KVP
    - 300mA at 150 KVP
  5. Indication meter :
    - KVP, Time, mA, mAs
    - LED Lamp full indication
  6. Radiographic setting mode
    - mA setting : 50mA to 500mA
    - KVP setting : 45KVP to 150KVP
    - Time setting : 1/120 to 5sec. (50 steps)
  7. Spot tradiographic mode
    - mA setting : 150mA to 500mA
    - KV setting : 45KVP to 125KVP
    - Maximum radiation time : 5min
  8. Anatomical mode
    - 72 preset anatomical programs.
  9. Self-diagonosing function
    - Over load. Back up, Error code
  10. Dimension (W x D x H)
    - 630 x 400 x 820mm

H/V Transformer

  1. Insulating oil-filled unit
  2. Maximum output ratings
    - 500mA at 100KVP
    - 300mA at 150 KVP
  3. Fluoroscopy output ratings
    - 0.5mA at 120KVP
    - 3mA at 100KVP
  4. Filament transformer
    - small output : 100V : 16V
    - large output : 100V : 24V
  5. High tension silicon rectification
  6. maximum output capacity : 45KVA

SMS-650-MF

Generator

  1. Micom control & digital display
  2. Power supply : 220V, 50/60Hz, single phase
  3. Pwer consumption : 50KVA
  4. Maximum output ratings
    - 600mA at 100 KVP
    - 300mA at 150 KVP
  5. Indication meter :
    - KVP, Time, mA, mAs
    - LED Lamp full indication
  6. Radiographic setting mode
    - mA setting : 50mA to 600mA
    - KVP setting : 45KVP to 150KVP
    - Time setting : 1/120 to 5sec. (50 steps)
  7. Spot radiographic mode
    - mA setting : 150mA to 600mA
    - KV setting : 45KVP to 125KVP
    - Time setting : 1/120 to 5sec (50steps)
  8. Fluoroscopic mode
    - mA setting : 0.5mA to 3.0mA
    - KV setting : 45KVP to 125KVP
    - Maximum radiation time : 5min
  9. Anatomical mode
    - 72 preset anatomical programs.
  10. Self-diagonosing function
    - Over load. Back up, Error code
  11. Dimension (W x D x H)
    - 630 x 400 x 820mm

H/V Transformer

  1. Insulating oil-filled unit
  2. maximum output ratings
    - 600mA at 100KVP
    - 300mA at 150KVP
  3. Fluoroscopy output ratings
    - 0.5mA at 120KVP
    - 3mA at 100KVP
  4. Filament transformer
    - small output : 100V : 16V
    - large output : 100V : 24V
  5. High tension silicon rectification
  6. Maximum output capacity : 50KVA

Related Keywords: x-ray


Inquire now


Other products