Click to enlarge image
|
Model Number |
SMS-5125-GM, 5150-G, 6150-G |
Diagnostic X-ray Generators
500mA/125kVp, 500mA/150kVp, 600 mA/150kVp Radiography X-ray Generator
- Microprocessor control system!!
- Digital display & membrane switch!!
- 72 preset anatomical programs!!
- Self-diagnosing function!!
- Good design & easy handling!!
SMS-5125-GM
Generator
- Micom control & digital display
- Power supply : 220V, 50/60Hz, single phase
- Pwer consumption : 35KVA
- Maximum output ratings
- 100mA at 100 KVP - 80mA at 125 KVP
- Indication meter :
- KVP, Time, mA, mAs - LED Lamp full indication
- Radiographic setting mode
- mA setting : 50mA to 500mA - KVP setting : 45KVP to 125KVP - Time setting : 1/120 to 5sec. (50 steps)
- Anatomical mode
- 72 preset anatomical programs.
- Self-diagonosing function
- Over load. Back up, Error code
- Dimension (W x D x H)
- 630 x 400 x 820mm
H/V Transformer
- Insulating oil-filled unit
- maximum output ratings
- 500mA at 100KVP - 300mA at 125KVP
- Filament transformer
- small output : 100V : 16V - large output : 100V : 24V
- High tension silicon rectification
- Maximum output capacity : 35KVA
- Dimension (W x D x H)
- 415 x 485 x 580mm
SMS-5150-G
Generator
- Micom control & digital display
- Power supply : 220V, 50/60Hz, single phase
- Pwer consumption : 45KVA
- Maximum output ratings
- 500mA at 125 KVP - 300mA at 150 KVP
- Indication meter :
- KVP, Time, mA, mAs - LED Lamp full indication
- Radiographic setting mode
- mA setting : 50mA to 500mA - KVP setting : 45KVP to 150KVP - Time setting : 1/120 to 5sec. (50 steps)
- Anatomical mode
- 72 preset anatomical programs.
- Self-diagonosing function
- Over load. Back up, Error code
- Dimension (W x D x H)
- 630 x 400 x 820mm
H/V Transformer
- Insulating oil-filled unit
- Maximum output ratings
- 500mA at 100KVP - 300mA at 150 KVP
- Filament transformer
- small output : 100V : 16V - large output : 100V : 24V
- High tension silicon rectification
- maximum output capacity : 45KVA
- Dimension (W x D x H)
- 415 x 485 x 580
SMS-6150-G
Generator
- Micom control & digital display
- Power supply : 220V, 50/60Hz, single phase
- Pwer consumption : 50KVA
- Maximum output ratings
- 600mA at 100 KVP - 300mA at 150 KVP
- Indication meter :
- KVP, Time, mA, mAs - LED Lamp full indication
- Radiographic setting mode
- mA setting : 50mA to 600mA - KVP setting : 45KVP to 150KVP - Time setting : 1/120 to 5sec. (50 steps)
- Anatomical mode
- 72 preset anatomical programs.
- Self-diagonosing function
- Over load. Back up, Error code
- Dimension (W x D x H)
- 630 x 400 x 820mm
H/V Transformer
- Insulating oil-filled unit
- maximum output ratings
- 600mA at 100KVP - 300mA at 150KVP
- Filament transformer
- small output : 100V : 16V - large output : 100V : 24V
- High tension silicon rectification
- Maximum output capacity : 50KVA
- Dimension (W x D x H)
- 415 x 485 x 580mm
|
|
|
|
| |
|
|
|